Smoke-free rooms, without a ban on smoking – with GEA Clarifair
|
The GEA solution enables smokers and non-smokers to coexist in harmony – without risks to their health, and without offensive odours
|
|
 The GEA Clarifair as a table model for standing smokers: this version is best suited, for example, for a coffee and chat corner in office buildings.
 The GEA Clarifair represents a “virtual smokers’ booth”. Although without walls, it ensures that smoke is completely captured from its immediate vicinity and filtered out.
 The GEA Clarifair can be installed on the floor or from the ceiling, and can be integrated into a central ventilation network (right half of the draw-ing).
|
|
|
GEA Clarifair combats smoke where it originates: at the serving counter, at the table, or in the break corner of an office building. The system directly evacuates blue haze – which means it has no chance to propagate and to mix with fresh air in the vicinity. GEA Clarifair pre-vents endangering health by passive smoking, and eliminates un-pleasant odours. A welcome side effect: the system also purifies the surrounding air in the room, and removes such pollutants as fine dust. A triple-stage filter system removes particles and odours The new GEA Clarifair room unit has an open design: it functions without a booth, and yet enables practically 100% capture and filtra-tion of tobacco smoke. Thanks to the various models and perform-ance levels available, it successfully meets the needs for a great variety of actual room-flow conditions. The Clarifair can be mounted on the floor or from the ceiling, and through a large inlet effectively intakes room air from its surrounding area. It passes the air through a noise suppressor, and on through a pre-filter. The next step is separation of smoke and other particles in a fine filter or electrostatic filter. After the air has been cleansed of gaseous pollutants by an activated-charcoal filter, it is systematically directed back into the room. Clarifair: a virtual smoker’s booth with 100% smoke capture In the area provided for smokers under the Clarifair, the system cap-tures virtually all the air, with the result that it removes the emitted smoke from up to 12 smokers. Clarifair intakes air from outside its pri-marily effective zone as well, with the result that neighbouring areas profit as well. Despite its high efficiency, the operational noise of the Clarifair is hardly perceptible.
|
|
|
|
Designed for new buildings and for retrofitting GEA Clarifair is equally effective in new buildings, or as a retrofit. It can be easily installed in buildings with ventilation and air condition-ing, without interference with existing systems. It is even possible to integrate the units into a ventilation system. In such applications, the intake air and the smoke can be directly passed into an exhaust-air duct system, in which case the GEA Clarifair functions effectively without filter components. GEA Clarifair is available in various design versions: for example, in models with a table for standing users, and as a ceiling-mounted version.
Technical data for the GEA Clarifair | Diameter of the system | 2.050 mm | | System height for floor-mounted model | 2.560 mm | | Number of smokers who have room under the model | 12 | | Air-flow rate ( Standard and High-Power models) | 1.500 / 2.100 m³/h | | Power rating ( Standard and High-Power models) | 0,45 / 0,87 kW | | Filter system | Particulate filter, absolute or electrostatic filter, activated-charcoal filter |
Download: Text incl. pictures as PDF file: gea_clarifair.zip (104 kB) High-res pictures: gea_clarifair_bilder.zip (2.148 kB)
|
|
|
|
|
|
|